Main Circuit Capacitor Service Life Coefficient (Measurement Value) (3008Hex-2BHex)
Main Circuit Capacitor Service Life Coefficient (Initial V
alue) (3008Hex-30Hex)
Service Life of Main Circuit Capacitor Remaining Time (3008Hex-4EHex)
Cumulative Run Time of Cooling Fan (3008Hex-2CHex)
Cumulative Run Time of Capacitors on Printed Circuit Boards (3008Hex-31Hex)
1st Startup Count for Motor (3008Hex-2DHex)
2nd Startup Counter for Motor (3009Hex-35Hex)
1st Cumulative Motor Run Time (3008Hex-5FHex)
2nd Cumulative Motor Run Time (3009Hex-34Hex)
User Preference Dataset Protection Function Selection (3020Hex-5FHex)
Monitor Exclusive Parameters (M, W Parameters)
Clear Alarm History (3008Hex-04Hex = 7)
When “7: Clear alarm history” is set to Data Initialization (3008Hex-04Hex), the alarm history and
various information at the time of the alarm are cleared to set to an alarm non-occurring state.
The alarm information of parameters (refer to 8-1-4 Alarm information on page
8-16) is initialized.
6-1-2
User Preference Dataset (Registration/Protection)
Set User Preference Dataset Registration/Protection by the following parameters. When “4: Restore
user defined data” is set to Data Initialization (3008Hex-04Hex), parameters are initialized using the
saved user preference datasets.
Parameter No. Function name Data Default data Unit
3020Hex-5EHex
User Preference Data-
set Registration
0: Disable
1: Store
0 -
3020Hex-5FHex
User Preference Data-
set Protection Function
Selection
0: Unprotected
1: Protected 0 -
Related function Data Initialization (3008Hex-04Hex)
The set values of parameters that have been changed from the factory defaults can be saved (regis-
tered) as user preference dataset. For parameters also that have not been changed from the factory
defaults, factory defaults can be saved (registered) as user preference dataset. Note, however, that
the following parameters are not targeted for saving as user preference datasets.
Main Circuit Capacitor Service Life Coef
ficient (Measurement Value) (3008Hex-2BHex)
Main Circuit Capacitor Service Life Coefficient (Initial Value) (3008Hex-30Hex)
Service Life of Main Circuit Capacitor Remaining Time (3008Hex-4EHex)
Cumulative Run Time of Cooling Fan (3008Hex-2CHex)
Cumulative Run Time of Capacitors on Printed Circuit Boards (3008Hex-31Hex)
1st Startup Count for Motor (3008Hex-2DHex)
2nd Startup Counter for Motor (3009Hex-35Hex)
1st Cumulative Motor Run Time (3008Hex-5FHex)
2nd Cumulative Motor Run Time (3009Hex-34Hex)
User Preference Dataset Protection Function Selection (3020Hex-5FHex)
Monitor Exclusive Parameters (M, W Parameters)
6 Basic Settings
6-6
M1 Series EtherCAT Type User’s Manual (I670)