A-4-10
A Group Parameter List (Motor 2 Parameters)
Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
3009 02 A01 2nd Maximum
Output Frequen-
cy
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
5.0 to 590.0
60.0 --- Hz Possible
03 A02 2nd Base Fre-
quency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
5.0 to 590.0
50.0 --- Hz Possible
04 A03 2nd Rated Volt-
age at Base Fre-
quency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
80 to 240 (200 V class series)
160 to 500 (400 V class series)
200 --- V Possible
05 A04 2nd Rated Volt-
age at Maximum
Output Frequen-
cy
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
80 to 240 (200 V class series)
160 to 500 (400 V class series)
200 --- V Possible
06 A05 2nd Manual Tor-
que Boost Volt-
age
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 20.0
Percentage with respect to 2nd Rat-
ed Voltage at Base Frequency (A03)
1.9
√
%
Possible
07 A06 2nd Motor Elec-
tronic Thermal
Characteristic se-
lection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
1: For a general-purpose motor with
shaft-driven cooling fan
2: For an inverter-driven motor non-
ventilated motor or motor with sepa-
rately powered cooling fan
1
√
--- Possible
08 A07 2nd Motor Elec-
tronic Thermal
Level
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00: Disable
0.01 to 118.8
21
√
A
Possible
09 A08 2nd Motor Elec-
tronic Thermal
Time Constant
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.5 to 75.0
5
√
min Possible
0A A09 2nd DC Injection
Braking Start
Frequency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 60.0
0.0
√
Hz Possible
Appendices
A-147
M1 Series EtherCAT Type User’s Manual (I670)
A-4 Lists of Manufacturer Specific Objects 2
(Inverter Parameters)
A
A-4-10 A Group Parameter List (Motor 2 Parameters)