4.14.6 Board Replacement Date & Time Setting
EXECUTION MODE
Normal mode
PROCEDURE
1. Turn the printer ON.
2. Start the Service Program and select Main Board Exchange Counter (or Power
Supply Unit Replacement Date & Time setting).
3. Click [Run]. When a confirmation message is displayed, press [OK].
4. Click [Finish].
5. Turn the printer OFF to finish the adjustment.
Figure 4-75. [Main Board Exchange Counter] Screen