9 - 140
9.5 Device Monitor Utility
9.5.5 Setting device to be monitored
9
UTILITY OPERATION
9.5.5 Setting device to be monitored
Set the device to be monitored.
POINT
The devices that can be monitored by 16-point register monitor are only randomly
accessible devices.
If the specified device does not accept random access, a device type error (-3) will
occur.
Refer to the following for random accessibility of each device.
Section 10.3.12
(1) Menu item to be selected
Select [Setting] [Device setting] from the menu bar.
(2) Dialog box
Figure 9.105 Device Setting dialog box
Table9.95 Explanation of Device Setting dialog box
Item Description
Device Type
Set the type ( Section 10.3.11), block No., and network No. of
the device to be monitored.
Device No.
Set the start No. of the device to be monitored.
(HEX: Hexadecimal, DEC: Decimal, OCT: Octal)
Register Device List Displays the registered devices as a list.
button
Registers the settings of Device type and Device No., and adds them
to the Register device list.
button
Select a changed device and click this button to change the registered
setting.
button
Select the device to be deleted and click this button to delete the
device from the Register device list.
Batch monitor 16-point register monitor
Setting
Change
Delete

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals