(5) Corrective actions for "MUtllfCom" events by event Nos.
Corrective actions for events that may occur in "MUtllfCom" are listed below by event
Nos.
(6) Corrective actions for "MMain" events by event Nos.
Corrective actions for events that may occur in "MMain" are listed below by event
Nos.
Table18.16 Corrective actions for "MUtllfCom" events by event Nos.
Event No. Event Corrective action
0xC0000000 A packet illegal error occurred.
Check the port No. used and change it if
necessary.
Change the IP address.
0xC0000001 An instruction error occurred.
Check the utility and C Controller module
versions.
0xC0000002 A socket generation error occurred.
Restart the C Controller module.
Please consult your local Mitsubishi service
center or representative, explaining the details
of the problem.
0xC0000003 A port acquisition error occurred.
Check the port No. used.
Check for overlap between the C Controller
module ports.
0xC0000004 A bind error occurred.
Restart the C Controller module.
Please consult your local Mitsubishi service
center or representative, explaining the details
of the problem.
Table18.17 Corrective actions for "MMain" events by event Nos.
Event No. Event Corrective action
0xC0000110 A script execution error occurred.
A system error in the C Controller module is
probable.
Please consult your local Mitsubishi service
center or representative, explaining the details
of the problem.
0xC0000111
One command (one line) in the script file has 129 or more characters.
(The C Controller module is in the status of a stop error [CPU error
code 2502], and stops executing the script command.)
Correct or delete the description of the script
file where the error occurred, and restart the C
Controller module.
( Section 18.3 (3) error code 2502)
0xC0000330 Failed in LAN access.
The parameter file (IP address setting area)
does not exist. Using the C Controller setting
utility, set the IP address or write the
parameters.
A system error in the C Controller module is
probable.
Please consult your local Mitsubishi service
center or representative, explaining the details
of the problem.