Development Unit
SM 4-49 D062/D063/D065/D066
Replacement
and
Adjustment
4. Lock plate [B] ( x 1)
After re-installation, the tab [C] should be behind the stay and its pin below
should be in the open track below.
1. Toner bottle unit [A] ( x 1, harness x 1, x 1)
The c-clamp is under the toner unit.
Lift the toner bottle unit off the pegs and lay it on a piece of newspaper to avoid
toner spill.
2. Bottom plate [B] (
x 3, harnesses x 2)
2 screws on the bottom, 1 screw on the side.
3. Toner supply motor bracket [C] (
x 2)
4. Toner supply motor [D] (
x 2)
Cleaning Requirement
The toner pan [E] must be cleaned at every PM interval (300 K).