Installation Requirements
SM 2-1 D062/D063/D065/D066
Installation
2. INSTALLATION
2.1 INSTALLATION REQUIREMENTS
2.1.1 OPERATING ENVIRONMENT
1. Temperature Range
Recommended: 15 °C to 25 °C (59 °F to 77 °F)
Possible: 10 °C to 32 °C (50 °F to 90 °F)
2. Humidity Range:
Recommended: 30% to 70 %RH
Possible: 15% to 80% RH (27 °C 80%, 32 °C 54%)
3. Ambient Illumination: Less than 1,500 lux (do not expose to direct sunlight or strong
light.)
4. Ventilation: Room air should turn over at least 3 times per hour
5. Ambient Dust: Less than 0.10 mg/m
3
6. If the place of installation is air-conditioned or heated, do not place the machine where
it will be:
Subjected to sudden temperature changes
Directly exposed to cool air from an air-conditioner
Directly exposed to heat from a heater
7. Do not place the machine where it will be exposed to corrosive gases.