Updating the Firmware
D062/D063/D065/D066 5-18 SM
The "Verify" procedure is not necessary but it is strongly recommended.
9. After the firmware is correctly updated, turn the main power switch off.
10. Push the SD card in a small distance to release it, then pull it out of the slot.
11. Turn the main power switch on, and check that the machine operates correctly.
Errors During Firmware Update
If an error occurs during a download, an error message will appear. The error code consists
of the letter "E" and a number ("E20", for example).
Error Message Table
No. meaning Solution
20 Cannot map logical address
Make sure the SD card is installed correctly, or
use a different SD card.
21 Cannot access memory HDD connection not correct, or replace hard disk.
22
Cannot decompress
compressed data
The ROM data on the SD card is not correct, or
data is damaged.
23
Error occurred when ROM
update program started
Controller program defective. If the second
attempt fails, replace the controller board.
24 SD card access error
Make sure the SD card is installed correctly, or
use a different SD card.
30
No HDD available for stamp
data download
HDD connection not correct or replace hard disks.
31
Data incorrect for continuous
download
Install the SD card with the remaining data
necessary for the download, then re-start the