Service Program Mode Tables
SM Appendix 4-77 D062/D063/D065/D066
Appendix:
Service
Program
Mode Tables
Adj Text/Photo recognition Level High Compression PDF DFU
4994
[0 to 2/1/1]
SP5xxx Mode
mm/inch Display Selection
5024
Selects whether mm or inches are used in the display.
Note: After selecting the number, you must turn the main power switch off and
on.
Europe/Asia model: [0 = mm / 1 = inch]
American model: [0 = mm / 1 = inch]
5037 Status Lamp Mode
0: OFF / 1: ON Not Used
Accounting Counter
5045
Selects the counting method if the meter charge mode is enabled with
SP5-930-001.
Note: You can change the setting only one time.
[0 to 1/ 1]
0: Development counter. Shows the total counts for color (Y, M, C) and black (K).
1: Paper counter. Shows the total page counts for: Black Total, Black Copies,
Black Prints.
5047 Paper Display
001 Backing Paper Display
Determines whether the tray loaded with paper printed on one side is displayed
on the operation panel.
[0 to 1/0/1]