Energy Save
D062/D063/D065/D066 7-2 SM
D062/D063 1 min.
D065 16 min.
D066 15 min.
Normally, Panel Off timer < Energy Saver timer < Auto Off timer. But, for example, if Auto
Off timer < or = Panel Off timer and Energy Saver timer, the machine goes immediately to
Off mode when the Auto Off timer expires. It skips the Panel Off and Energy Saver modes.
Example
Panel off: 1 min.
Low power: 15 min.
Auto Off: 1 min.
The machine goes to Off mode after 1 minute. Panel Off and Low Power modes are
not used.
Return to Stand-by Mode
Low Power Mode
The recovery time depends on the model and the region.
D062/D063/D065: 10 sec.
D066: 30 sec.
Off/Sleep Mode
Recovery time.
D062/D063: Max 30 sec.
D065: Max 60 sec.
D066: Max 300 sec.
Recommendation
We recommend that the default settings should be kept.
If the customer requests that these settings should be changed, please explain that
their energy costs could increase, and that they should consider the effects on the
environment of extra energy use.
If it is necessary to change the settings, please try to make sure that the Auto Off timer
is not too long. Try with a shorter setting first, such as 30 min., then go to a longer one
(such as 60 min.) if the customer is not satisfied.
If the timers are all set to the maximum value, the machine will not begin saving energy
until 240 minutes has expired after the last job. This means that after the customer has
finished using the machine for the day, energy will be consumed that could otherwise