Sub Scan Magnification
 Make a temporary test chart as shown above using A3/DLT paper.
1. Place the temporary test chart on the ADF and make a copy from one of the feed
stations.
2. Check the magnification, and adjust using the following SP modes if necessary. The
specification is ±1%.
SP mode
Sub scan magnification SP6-006-5