Bit Switches - 1
D361/D510 74 SM
4.3 BIT SWITCHES - 1
 Do not adjust a bit switch or use a setting that is described as "Not used", as this
may cause the machine to malfunction or to operate in a manner that is not
accepted by local regulations. Such bits are for use only in other areas, such as
Japan.
Default settings for bit switches are not listed in this manual. Refer to the System
Parameter List printed by the machine.
4.3.1 SYSTEM SWITCHES
System Switch 00 (SP No. 1-101-001)
No Function Comments
0
Dedicated transmission
parameter programming
0: Disabled
1: Enabled
Set this bit to 1 before changing any dedicated
transmission parameters.
Reset this bit to 0 after programming dedicated
transmission parameters.
1 Not used Do not change
2
Technical data printout on the
Journal
0: Disabled
1: Enabled
1: Instead of the personal name, the following
data are listed on the Journal for each G3
communication.