Rockwell Automation Publication 2198-UM001M-EN-P - November 2022 35
Chapter 2 Plan the Kinetix 5500 Drive System Installation
Passive Shunt Considerations
The Kinetix 5500 drives all include an internal shunt that is wired to the shunt
resistor (RC) connector at the factory. Bulletin 2097-Rx external passive shunts
are available to provide additional shunt capacity for applications where the
internal shunt capacity is exceeded.
Catalog numbers 2097-R6 and 2097-R7 are shunt resistors without an
enclosure.
Figure 13 - External Passive Shunts
How the Bulletin 2097-Rx shunts connect to Kinetix 5500 drives is explained in
External Passive-shunt Resistor Connections on page 97
and illustrated with
interconnect diagrams in Shunt Resistor Wiring Example on page 184.
IMPORTANT Keep the internal shunt wires connected unless you have an external
passive shunt to connect.
Table 15 - Bulletin 2097 Passive Shunt Options
Kinetix 5500 Drives
Cat. No.
Internal Shunt Specifications
External Shunt Resistor
(1)
Compatibility Cat. No.
(1) Shunt resistor selection is based on the needs of your actual hardware configuration.
Ω W 2097-R7 2097-R6
2198-H003-ERSx
100 30
X—
2198-H008-ERSx X—
2198-H015-ERSx
60 50
X—
2198-H025-ERSx X—
2198-H040-ERSx —X
2198-H070-ERSx 40 75 — X
2097-R6 and 2097-R7
Shunt Resistors
Table 16 - External Shunt Module Specifications
Shunt Module
Cat. No.
Resistance
Ω
Continuous Power
W
Weight, Approx
kg (lb)
2097-R6 75 150 0.3 (0.7)