Changing the assignment of the digital inputs
Parameter Description
p0840[0…n] =
722.x
BI: ON/OFF1 (ON/OFF1)
Example: p0840 = 722.3 ⇒ DI3: ON/OFF1
p1113[0…n] =
722.x
BI: Setpoint inversion (reversing)
7.4.2 Two-wire control, method 2
W
W
W
672367236723
&ORFNZLVH
&RXQWHUFORFNZLVH
212))
&RXQWHUFORFNZLVH
212))
&ORFNZLVH
6SHHGVHWSRLQW
&RPPDQGKDVQRHIIHFW
Commands "ON/OFF1 clockwise rotation" and "ON/OFF1 counter-clockwise rotation" switch
on the motor - and simultaneously select a direction of rotation. The converter only accepts a
new command when the motor is at a standstill.
ON/OFF1 clockwise rota‐
tion
ON/OFF1 counter-clock‐
wise rotation
Function
0 0 OFF1: The motor stops.
1 0 ON: Clockwise motor rotation.
0 1 ON: Counter-clockwise motor rotation.
1 1 ON: The motor direction of rotation is dened
by the command that rst reaches state "1".
Parameters
Select two-wire control, method2
Parameter Description
p0015=61 Macro drive unit
You must carry out quick commissioning in order to set parameter p0015.
Assigning digital inputs DI to the commands:
DI0: ON/OFF1 clockwise rotation
DI1: ON/OFF1 counter-clockwise rotation
Advanced commissioning
7.4Controlling clockwise and counter-clockwise rotation via digital inputs
SINAMICS G115D Wall Mounted distributed drive
138 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA