7.13 Free function block
Overview
The free function blocks permit congurable signal processing in the converter.
The following free function blocks are available:
• AND, OR, XOR, and NOT logic
• RSR (RS ip-op), DSR (D ip-op) ip-ops
• Timers MFP (pulse generator), PCL (pulse shortening), PDE (ON delay), PDF (OFF delay), and
PST (pulse stretching)
• ADD (adder), SUB (subtractor), MUL (multiplier), DIV (divider), AVA (absolute value
generated), NCM (comparator), and PLI (polyline) arithmetic functions
• LIM (limiter), PT1 (smoothing), INT (integrator), DIF (dierentiator) controllers
• NSW (analog) BSW (binary) switches
• LVM limit value monitoring
The number of free function blocks in the converter is limited. You can only use a function
block once. The converter has 3 adders, for instance. If you have already congured three
adders, then no other adders are available.
Further information
Further information about the application description for the free function blocks is provided on
the Internet:
FAQ (https://support.industry.siemens.com/cs/ww/en/view/85168215)
7.14 Selecting physical units
7.14.1 Motor standard
Selection options and parameters involved
The converter represents the motor data corresponding to motor standard IEC or NEMA in
dierent system units: SI units or US units.
Advanced commissioning
7.14Selecting physical units
SINAMICS G115D Wall Mounted distributed drive
230 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA