7.9.2.4 Turntable, three positions and two speeds (p3393 = 8)
Overview
With p3393 (conveyor technology application) set to 8, the converter enables a turntable in a
conveyor system to rotate in either positive or negative direction with variable speeds and stop
at three dedicated positions.
Six sensors are required to signal the limit positions for the motor to stop or decelerate. In
the mechanical setup of the conveyor system, you must install the stop sensor and low speed
sensor in a line. So do the stop and low speed cams. Besides, when setting up the cams, the
low speed cam must be longer than the stop cam.
Precondition
You interconnect the signals of the sensors with the digital inputs of your choice.
Depending on the speci󹪝c application and mechanical setup, you must set end position
shutdown active (p3392) to 1, so as to limit the turntable movement between the dedicated
positions.
Advanced commissioning
7.9Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 205

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals