EasyManuals Logo
Home>Siemens>DC Drives>SINAMICS G115D

Siemens SINAMICS G115D User Manual

Siemens SINAMICS G115D
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #507 background imageLoading...
Page #507 background image
12.3.18 Torque arms with slip-on gearboxes
12.3.18.1 General information regarding torque arms
Torque arms can absorb the reaction torque and the weight of the gearbox.
NOTICE
Dangerous transient torques due to excess backlash
Take care to prevent the torque arm from causing excessive constraining forces, e.g. due to the
driven shaft running out-of-true.
NOTICE
Impermissible gearbox loading caused by incorrect mounting
Do not tension torque arms when mounting.
NOTICE
Damage to the rubber elements caused by solvent
Solvents, oils, greases, and fuels damage rubber elements.
Avoid contact at all times.
12.3.18.2 Mounting torque arms on parallel shaft gearboxes
We recommend using pretensioned, damping rubber elements.
Fixing accessories such as brackets, bolts, nuts, etc. are not included in the scope of supply.
\
5=
5=
\
\
FPLQ
O[
G
G
G
G
O
Figure12-26 Suggestion for mounting torque arms on F.29 - F.89
Size Rubber bu󹪜er Washer
Unten‐
sioned
Tensioned
l1 l1x d6 d1 d5 c6
min
mm mm mm mm mm mm
29 15 14.0 30 10.5 40 4
39 13.5
Additional information on the SIMOGEAR geared motor
12.3Speci󹪝c data gearbox
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 505

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals