12.1.12 Inspecting the geared motor
Perform a scheduled inspection of the gearbox once a year in accordance with the possible
criteria listed in General notes about maintenance work (Page512).
Check the geared motor in accordance with the criteria speci󹪝ed in General motor
information (Page447)andGeneral information gearbox (Page479).
Touch up damaged paintwork carefully and professionally.
12.1.13 Disposal
WARNING
Incorrect disposal of used oil
Incorrect disposal of used oil is a threat to the environment and health.
After use, oil must be taken to a used oil collection point. The addition of foreign substances
such as solvents, brake and cooling 󹪞uid is prohibited.
Avoid prolonged contact with the skin.
Empty the used oil from the gearbox. The used oil must be collected, stored, transported and
disposed of in accordance with regulations. Do not mix polyglycols with mineral oil. Dispose
of polyglycols separately.
Please observe country-speci󹪝c laws. Under German law, to allow optimal treatment of the
oil (§4VIUsed Oil), oils with di󹪜erent disposal codes must not be mixed with one another.
Collect and dispose of used oil in accordance with regulations.
Remove oil spillages immediately with an oil-binding agent in compliance with
environmental requirements.
Dispose of the housing parts, gears, shafts, and rolling bearings of the geared motor as scrap
metal.
Dispose of packaging material in accordance with regulations.
Table 12-2 Disposal codes for gear oils
Type of oil Designation Disposal code
Mineral oil CLPISOVG220 130205
Polyglycols CLPISOPGVG220,
CLPISOPGVG460,
CLPISOH1VG100,
CLPISOH1VG460
130208
Poly-Alpha-Ole󹪝nes CLPISOPAOVG68,
CLPISOPAOVG220,
CLPISOPAOVG460
130206
Biologically degradable oils CLPISOEVG220 130207
Additional information on the SIMOGEAR geared motor
12.1General information geared motor with SINAMICS G115D Motor Mounted / Wall Mounted
SINAMICS G115D Wall Mounted distributed drive
438 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals