If you assign the address via a commissioning tool, you must back up the settings so that
they are not lost if the power fails.
Address range for Single Slave converter, pro󹪝le 7.F.E
p2012[1]:0…31, range for the A address, 0A…31A
Address range for Dual Slave converter, pro󹪝le 7.A.5 or 7.A.E
p2012[0]:0…31, 33…63 for slave 1: 
p2012[1]:0…31, 33…63 for slave 2:
with
0…31range for the A address, 0A…31A
33…63range for B address, 1B…31B
5.14.4 Using the AS-i Programmer
Setting the slave address with the AS-i Address Programmer
The converter contains two logical AS-i slaves. Either slave can be assigned an address in the
range 1A...31A or 1B...31B. The addresses can be allocated to the slaves sequentially, for
example, 3A and 4A, 10B and 11B or they can occupy the same number using extended
addressing, for example, 20A and 20B. If necessary they can have completely di󹪜erent
unassociated addresses, for example, 14A and 16B.
The decision on how to allocate these addresses must also take into account the addressing
used in the PLC program by either adherence to the memory map of the AS-i master or the
way in which the inputs and outputs can be allocated by the PLC hardware con󹪝guration.
The default address of both slaves is 0.
Setting the AS-i address of slave 1
1. Plug the AS-i Programmer into the addressing socket (interface X03) of the converter.
2. Turn the dial on the Programmer to the ADDR position. The display
will indicate that this mode has been selected.
3. Press the button; the screen will display the text, SEt 0 with a
small 󹪞ashing 0 to the left of the display.
4. Press the button until you reach the required number.
By pressing both the and simultaneously, you can toggle between A and B
identi󹪝ers of the address.
5. Press the button to con󹪝rm the selected address.
ProG is momentarily displayed, followed by AddrES.
The number allocated to slave 1 is now shown at the bottom of the
display.
Wiring
5.14Connecting to AS-i
SINAMICS G115D Wall Mounted distributed drive
98 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals