Permitted oil sump temperatures -40° C to +100° C.
Seal to handle increased environmental stress (optional)
This seal is equipped with an additional 󹪝ber disk. The disk so provides increased protection
against higher environmental stress caused by dirt and dust.
Permitted oil sump temperatures -20° C to +80° C.
High temperature-resistant seal (optional)
The deployed radial shaft sealing rings are made of a temperature-resistant material.
Permitted oil sump temperatures -25° C to +110° C.
12.3.5 Cooling
NOTICE
Dust deposits prevent heat radiation
Dust deposits prevent heat radiation and cause a high housing temperature.
Keep the gearbox free from dirt, dust, etc.
The gearbox does not normally require additional cooling. The generously dimensioned
housing surface is su󹪟cient for dissipating heat losses where there is free convection. If the
housing temperature exceeds a value of+80°C, please contact Technical Support.
Additional information on the SIMOGEAR geared motor
12.3Speci󹪝c data gearbox
SINAMICS G115D Wall Mounted distributed drive
482 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals