EasyManuals Logo
Home>Siemens>DC Drives>SINAMICS G115D

Siemens SINAMICS G115D User Manual

Siemens SINAMICS G115D
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
5.12 Connecting the digital inputs and outputs
5.12.1 Interface description - X07/X08/x05
The G115D converter has four digital inputs (DI 0 to DI 3) and two bidirectional digital inputs/
outputs (DIO 24 and DIO 25). Digital inputs DI 0 and DI 1 can be used to connect an HTL encoder
(track A/B). Digital inputs DI 2 and DI 3 can be used for the safety functions. The bidirectional
DI/DO can be parameterized as digital inputs or digital outputs with parameter p0728.
Connector variant
M12 A-coding connector, 5-pin, female
Digital inputs (X07, X08) and bidirectional digital inputs/outputs (X05)
X07 Pin Signal Description
2
5
4
1 3
1 1L+ Unswitched 24 V
2 DI1 Digital input 1
3 1M Unswitched 0 V
4 DI0 Digital input 0
5 FE Functional earth
X08 Pin Signal Description
2
5
4
1 3
1 1L+ Unswitched 24 V
2 DI3 Digital input 3
3 1M Unswitched 0 V
4 DI2 Digital input 2
5 FE Functional earth
X05 Pin Signal Description
2
5
4
1 3
1 2L+ Switched 24 V
2 DIO25 Bidirectional digital output/input 25
3 2M Switched 0 V
4 DIO24 Bidirectional digital output/input 24
5 FE Functional earth
Wiring
5.12Connecting the digital inputs and outputs
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 81

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals