Page #394 background imageLoading...
Page #394 background image
Option 2: The machine manufacturer knows the serial number of the new converter
and the serial number of the memory card
1. The end customer provides the machine manufacturer with the following information:
For which machine must the converter be replaced?
What is the serial number (r7758) of the new converter?
What is the serial number of the memory card?
2. The machine manufacturer performs the following steps online on the prototype machine:
Deactivating know-how protection
Activating and deactivating know-how protection (Page366)
Enter the serial number of the new converter in p7759.
Enter the serial number of the customer's memory card as reference serial number in
p7769.
Activate know-how protection with copy protection. "Copy RAM to ROM" must be
activated.
Activating and deactivating know-how protection (Page366)
Write the con󹪝guration with p0971 = 1 to the memory card.
Copy the encrypted project from the card to the associated PC.
Send the encrypted project to the end customer, e.g. via e-mail.
3. The end customer copies the project to the Siemens memory card that belongs to the
machine, inserts it in the converter and switches on the power supply of the converter.
4. When powering up, the converter checks the serial numbers of the card and when there is a
match, the converter goes into the "ready to start" state.
If the numbers do not match, then the converter signals fault F13100 (no valid memory
card).
You have transferred the converter settings to the new converter.
10.3 Replacing the spare parts
For more information on the spare parts of the geared motors, refer to the following chapter:
Spare parts list, motor (Page474)
Replacement part lists gearbox (Page565)
Corrective maintenance
10.3Replacing the spare parts
SINAMICS G115D Wall Mounted distributed drive
392 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals