DE
F
E
D
F
Q
/RZVSHHGVHQVRUQHJDWLYH
S
/RZVSHHGVHQVRUFHQWHU
S
6WRSVHQVRUFHQWHU
S
6WRSVHQVRUFHQWHU
S
/RZVSHHGVHQVRUFHQWHU
S
6WRSVHQVRUFHQWHU
S
6WRSVHQVRUFHQWHU
S
3RVLWLRQ3RVLWLRQ3RVLWLRQ
3RVLWLRQ3RVLWLRQ
/RZVSHHGVHQVRU
SRVLWLYHS
6WRSVHQVRUSRVLWLYH
S
6WRSVHQVRUQHJDWLYH
S
(QGSRVLWLRQVKXWGRZQDFWLYDWHGS
+LJKVSHHGVHWSRLQW
S
+LJKVSHHGVHWSRLQW
S
/RZVSHHGVHWSRLQW
S
/RZVSHHGVHWSRLQW
S
Note
The motor will have the following behavior with the end position shutdown (p3392 = 1) and
level-triggered sensor signals (p3394 = p3395 = 1 or 2) activated:
• Once a stop or low speed sensor at the positive or negative position is triggered, the motor
stops and goes to low speed even if the level is canceled.
• Once a stop or low speed sensor at the center position is triggered, the motor stops and goes
to low speed; if the level is cancelled, then the motor runs again.
Advanced commissioning
7.9Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 207