Programming and Operating Manual (Turning)
10 01/2017
Additional information about keys
<CTRL + P>: Creates a screenshot of the actual user interface
<CTRL + S>: Saves startup archives and action logs to a USB stick
<CTRL + D>: Displays pre-defined slides on the screen
<ALT + D>: Saves action logs to a USB stick
Calls the calculator function when you position the cursor on the desired input field
<CTRL + cursor key>: Changes the screen backlight brightness by an increment of 10% (bright-
ness range: 10% to 100%)
Note that after you release the key combination, the HMI saves your brightness setting and the
brightness bar disappears after a few seconds.
The graphical symbols shown on the six keys above are available only on the PPU161.3 and
PPU160.2.
Enters the upper character shown on the alphabetic/numeric keys concerned
+
Opens the system data operating area
In the program editor, pressing this key moves the cursor to the beginning of the selected pro-
gram block.
•
Toggles between entries in the input field
• Enters the "Set-up menu" dialog box at NC startup
Enables user-defined extension applications, for example, generation of user dialog boxes with
the EasyXLanguage function. For more information about this function, see the SINUMERIK
808D/SINUMERIK 808D ADVANCED Function Manual.
Status indicators
Indicator
Status and meaning
"POK"
•
Solid green: The power supply for the control system is switched on.
"RDY"
• Solid green: The control system is ready and the PLC is in run mode.
• Solid red: The control system is in stop mode.
• Solid orange: The PLC is in stop mode.
•
Flashing orange: The PLC is in power-up mode.
"TEMP"
• Off: The temperature of the control system is within the specified scope.
•
Solid orange: The temperature of the control system is beyond the scope.

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals