Programming and Operating Manual (Turning)
01/2017
255
Note
Before executing M functions, make sure all the axes are in safe positions.
Select the machining operating area.
Open the "T, S, M" window.
Press this key to move the cursor to the input field for M functions, and enter the desired
value, for example, "8".
Press this key on the MCP to activate the coolant function. Now you can see the corr
e-
sponding status indicator is on, which indicates the coolant s
upply is switched on.
CP to stop the coolant function.
tkey to return to the main screen of the machining operating area.
Setting the relative coordinate system (REL)
Operating sequence
Select the machining operating area.
Press this softkey to switch the display to the relative coordinate system.
Use the cursor keys to select the input field, and then enter the new position value of the
reference point in the relative coordinate system.
Use this key to activate the values after each entry.