A-22
SERVICE SPECIFICATIONS - Starting System, Charging System
STARTING SYSTEM
CHARGING SYSTEM
Pre-heating
system
Light lighting time
Supper glow type
Fixed delay type
HZJ and HDJ ex. (Europe and Australia)
PZJ, HZJ75, HZB and HDB
ex. (Europe and Australia) 12 V type
24 V type
Water temp, sensor resistance
at-2O°C (-4°F)
at 0°C (32°F)
at 20°C (68°F)
at40°C (104°F)
at 60°C (140°F)
at 80°C (176°F)
See pages ST-3, 4
Approx. 5 seconds
Approx. 6 seconds
Approx. 5 seconds
10 - 20 kfi
4-7kO
2-3 kfl
0.9 - 1.3 kQ
0.4-0.7 kfi
0.2-0.4 kQ
Starter
Rated voltage and output power
No-load characteristic
Current 12 V type
24 V type
rpm
Commutator Outer diameter STD
Limit
Undercut depth STD
Limit
Circle runout Limit
Brush Length STD
Limit
Spring installed load
12 V 2.5 kW, 24 V 4.5 kW
180 A or less at 11.0 V
90 A or less at 23.0 V
3,500 rpm or more
36.0 mm 1.417 in.
35.0 mm 1.378 in.
0.7-0.9 mm 0.028 - 0.035 in
0.2 mm 0.008 in.
0.05 mm 0.0020 in.
20.5-21.0 mm 0.807-0.827 in.
13.0 mm 0.512 in.
3.2-4.0 kg (7.1 -8.8 Ib, 31 -39 N)
Drive belt deflection and tension See page A-2
Battery specific gravity when fully charge at 20°C (68°F)
95D31R and 95D31 L
ex. (95D31R and 95D31 L)
1.25-1.27
1.27-1.29
Alternator
Rated output
Rotor coil resistance 12V type
24 V type
Slip ring diameter STD
Limit
Brush exposed length STD
Limit
1 2 V 45 A, 1 2 V 55 A, 1 2 V 60 A, 1 2 V 80 A,
1 2 V 1 00 A, 24 V 30A, 24 V 55 A
2.7-3.1 Q
1,0-1,4 SI
14.2-14.4 mm 0.559 - 0.567 in.
12.8 mm 0.504 in.
10.5 mm 0.413 in.
1.5 mm 0.059 in.
Alternator
regulator
Regulating voltage
12 V type at 25°C (77°F)
at115°C (239°F)
24 V type at 25°C (77°F)
at115°C (239°F)
14.0-15.0 V
13.5-14.3 V
27.7-28.7 V
26.0-28.7 V