DVP-ES3/EX3/SV3/SX3 Series Hardware and Operation Manual
4-30
_4
MPU
EXT
1 2
EXT
3
EXT
4
EXT
PLC Model
Number
of inputs
Number
of outputs
Input number
Output
number
MPU SX3 8 6 X0~X7 Y0~Y5
EXT1 16SP11T 8 8 X20~X27 Y20~Y27
EXT2 08SM11N 8 0 X30~X37 -
EXT3 06SN11R 0 6 - Y30~Y35
EXT4 08SP11R 4 4 X40~X43 Y40~Y43
Though the 3
rd
extension module 06SN11R will be regarded as a module with 8 output points, the
number of corresponding actual output points will only be 6; the last 2 output points are excluded.
Though the 4
th
extension module 08SP11R will be regarded as a module with 8 input points and 8
output points, the number of corresponding actual output points will only be 4 and input points will only
be 4; the last 4 input and 4 output points are excluded.
To have a more orderly arrangement, it is recommended to install modules with true to number of points
first.
4.2.2 Notes on Installation
System integrators shall be responsible for assembly of the control system and the safety of the system
integration.
If using the device other than those described in the standard, or in environments that do not meet the
specifications in this manual, the designed protection for the device in the presence of conducted and/or
radiated interference may be reduced.
Make sure to use certified power supplies with dual insulation and Safety Extra-Low Voltage (SELV)
output and ensure that they comply with UL60950 or UL62368 or UL61010-1 and UL61010-2-201, either
LPS (Limited Power Source) or LE (Limited Energy) requirements.
Use only a clean, dry and soft cloth to clean this module.
Before a module is installed, please make sure of the size of the module. To ensure sufficient installation
space, you must take into account the size of the communication cable connector and the room which
needs to be reserved.
Make sure that the work environment conforms to the specifications for the products. It is necessary to
take into account basic temperature/humidity control and dust/corrosion prevention.
Electromagnetic interference can result in system malfunction. Therefore, you must design the EMC
carefully. Please refer to Appendix C in this manual for more information on EMC standards.
If components such as screws and washers are specified in the manual, use components conforming to
the specifications.
If a cable is connected to a communication port, make sure the cable connector is properly joined to the
port on the module.

Table of Contents

Other manuals for Delta DVP-ES3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-ES3 Series and is the answer not in the manual?

Delta DVP-ES3 Series Specifications

General IconGeneral
BrandDelta
ModelDVP-ES3 Series
CategoryController
LanguageEnglish

Related product manuals