APPENDIX B : COMPRESSOR DRIVEN AIRDRYER
B--6 20950 Issue 1 April 98
SPECIFICATION
Dimensions (overall):
Height: 275mm
Width: 385mm
Depth: 200mm
Weight: 8.5kg
Environment:
Temp. Range: 5 --45 C operating.
Humidity: 10 -- 90% RH
non--condensing.
Electrical
Requirements:
90--132V/180--264V, 50/60Hz, single phase,
switch selectable.
Performance:
Air flow: 2.0--2.2 litres/min
Output humidity: < 40% RH.
Internal operating
pressure:
4 bar set to 2 bar.
Acoustic Noise Level: Not more than 70dBA.
PRODUCT SAFETY
Certain parts of the airdryer must not be replaced by other types
without approval of the Design Authority. These parts are as follows.
PART
NO.
DESCRIPTION MANUFACTU
RER
MANUF. PART
NO.
11588 Voltage Selector ITW SE 1022 18--000--042
30430 Compressor 90--132V
50/60Hz
KNF PJ 13504_NPK09
13654 Transformer Avel D4020
23387 PCB Domino
10606 Isolator K. Moeler Ltd TO--1--102/EA/SV
B
11191 Fuseholder Schurter 031.1133
12172 Mains Filter Ducatti EFBF--3
30419 Filter Assy Low
Frequency
Domino
11340 Fan 110V Papst 4600N
37775 Cable Assy Mains
Output
Domino
30414 Cable Assy Power
Supply
Domino