UTILITY OPERATION
9.2 C Controller Setting Utility
9.2.5 Operating Module monitor screen
9 - 27
9
UTILITY OPERATION
10
FUNCTIONS AND
PROGRAMMING
11
OVERVIEW OF
MULTIPLE CPU
SYSTEM
12
MULTIPLE CPU
SYSTEM
CONFIGURATION
13
MULTIPLE CPU
SYSTEM
CONCEPT
14
COMMUNICATIONS
BETWEEN CPU
MODULES
15
PARAMETERS
ADDED FOR
MULTIPLE CPU
16
PRECAUTIONS FOR
USE OF AnS SERIES
MODULE
(d) Monitor and test
Module monitor and test (forced output of output (Y), forced write to buffer
memory and CPU shared memory) performed on this screen are executed for the
module installed to "Slot No." set on this screen.
They do not depend on the data in the "Type" field of the parameter setting (I/O
assignment setting).
Note that only the modules controlled by the C Controller module can be tested.
When monitoring or forced writing to the buffer memory is performed to the CC-
Link module, which the Block guarantee of cyclic data per station is set to be
enabled, the cyclic data are automatically refreshed.
Note that the data are automatically refreshed only when the monitoring or forced
writing to the buffer memory is performed for the range of link refresh devices
(buffer memory), which correspond to the stations set in the CC-Link master
station parameters (Station information setting). (For details of the range, refer to
"Slave station offset, size information" (buffer memory address: 3E0
H to 5DFH) in
the buffer memory list for the CC-Link module.)
For details of the block guarantee of cyclic data per station, refer to the following.
Section 4.3.1
Note also that the following areas are not refreshed when monitoring or forced
writing to the buffer memory is performed.
• The write (transmission) area of link refresh devices (buffer memory) is not
refreshed when monitoring is performed.
• The read (reception) area of link refresh devices (buffer memory) is not
refreshed when the forced writing to the buffer memory is performed.
(e) Precautions for changing the module configuration
When the module configuration has been changed after a start of the C Controller
setting utility, performing any of the following operations updates the module
configuration information.
• Make the connection target setting.
• Click the button on the <<Module monitor>> tab.
• Click the button on the <<Module monitor>> tab.
Start monitor
Information