EasyManuals Logo
Home>Mitsubishi>Controller>MELSEC Q Series

Mitsubishi MELSEC Q Series User Manual

Mitsubishi MELSEC Q Series
664 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #294 background imageLoading...
Page #294 background image
9 - 44
9.2 C Controller Setting Utility
9.2.7 Operating System setting screen
9
UTILITY OPERATION
(2) Intelligent function module interrupt event setting screen
Set the data for the interrupt events
*1
of the intelligent function module.
* 1 An interrupt event is an event for interrupt notification that will occur in response to an interrupt
from the intelligent function module.
The following indicates the interrupt event Nos. and interrupt factors.
(To next page)
Figure 9.40 Intelligent function module interrupt event setting screen
Table9.23 Explanation of Intelligent function module interrupt event setting screen
Item Description
Reference
section
Interrupt event start No.
Set the start No. of the interrupt notification event that will occur in
response to an interrupt from the intelligent function module.
(Initial value: None, Setting range: 50 to 255)
4.14
Interrupt event No. of module
Set the number of interrupt notification events that will occur in response
to interrupts from the intelligent function module.
(Initial value: None, Setting range: 1 to 16)
4.14
Start I/O No.
Set the start I/O No. of the intelligent function module.
(Initial value: None, Setting range: 0000 to 0FF0, 3E00 to 3E30)
4.14
Start SI No.
Set the start SI No. (interrupt factor No.) of the intelligent function module.
(Initial value: None, Setting range: 0 to 15)
4.14
button
Checks whether the settings are correct or not.
button
Saves the settings and closes the "Intelligent function module interrupt
event setting" screen.
button
Closes the "Intelligent function module interrupt event setting" screen
without saving the settings.
Table9.24 List of interrupt event No. and interrupt factors
Interrupt event No. Interrupt factor
0
Interrupt by QI60
1st point
1 2nd point
23rd point
3 4th point
4 5th point
5 6th point
6 7th point
7 8th point
8 9th point
9 10th point
Check
End
Cancel

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series