Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
249
Defining the service planner
With the service planning function, you can set up maintenance tasks that have to be performed at certain intervals (for
example, top up oil, change coolant). An alarm appears as a reminder when the interval expires.
A list is displayed of all the maintenance tasks that have been set up together with the time remaining until the end of the
specified maintenance interval.
Position of the maintenance task in the PLC interface
Name of the maintenance task
Maximum time until next servicing in hours
Time in hours at which an initial warning is displayed
Number of warnings that can be
acknowledged by the operator before an alarm message is output for the last time
Time until the interval expires in hours. The remaining time cannot be edited.
Display of the current status of a maintenance task
: The maintenance task has been started.
: The maintenance task is completed.
Creating a new maintenance task
Proceed as follows to create a new maintenance task:
n the system data operating area.
Press this key on the PPU to view the extended softkeys.
Open the window of service planning.
Press this softkey to open the dialog box for creating a new task.
in the respective input fields.
Press this softkey to confirm your settings, and the new maintenance task displays on the
screen.
e vertical softkeys as required in the service planning window to com-
plete the following operations:
Acknowledges the selected task which has been completed
Deletes the selected task