Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
431
Axis/spindle signals
17.10.1
Transferred M and S functions, axis specific
M function for spindle (DINT)
4 S function for spindle (REAL)
Signals to axis/spindle
Common signals to axis/spindle
Signals to axis/spindle [r/w]
0
1 Override
active
Position
measuring
Position
measuring
Follow up
mode
Axis spindle
disable
2
Clamping in
progress
Distance-
to-
go/spindle
Drive ena-
ble
4 3 2 1
3 Axis/spindle
enable
program
Veloci-
ty/spindle
speed limit-
Enable
approach to
fixed stop
Feed 4 Feed 3 Feed 2 Feed 1
4
Rapid trav-
erse over-
Traverse
key disable
Feedrate
stop/spindle
Plus Minus 2 1
5
1)
Continuous
Var. INC 10000 INC 1000 INC 100 INC 10 INC 1 INC
7 Contour-
handwheel
direction of
rotation
8 Request
PLC ax-
is/spindle
Activation
signal when
this byte is
changed
Request
NC ax-
is/spindle
The machine function is only entered if the signal "INC inputs in the operating-mode signal range active"