375
Frame size
FSA
FSB
FSC
Certification
Outline dimensions (W × H × D, mm)
80 × 180 × 200
100 × 180 × 220
140 × 260 × 240
Net weight 1.86 kg 1.87 kg 2.445 kg 2.505 kg 2.565 kg 5.62 kg 5.725 kg
1)
The values here are given at rated load.
2)
The overvoltage threshold is 820 VDC; the undervoltage threshold is 320 VDC.
15.2.2
SINAMICS V70 spindle drives
Frame size
FSB
FSC
FSD
Article number
6SL3210-5DE...
21-1UA0
21-3UA0
22-0UA0
23-0UA0
24-0UA0
Rated output current
10.5 A
12.9 A
19.6 A
29.8 A
37.6 A
Max. output current
21 A
25.8 A
39.2 A
59.6 A
75.2 A
Max. supported motor power
3.7 kW
3.7 kW
7.5 kW
11 kW
15 kW
Output frequency 0 Hz to 400 Hz
Power supply
Voltage/frequency
3 phase 380 VAC to 480 VAC, 50/60 Hz
Permissible supply configuration TN, TT, IT
Permissible voltage fluctuation -15% to +10%
Permissible frequency fluctuation
-10% to +10%
Rated input current
13.2 A
16.2 A
24.5 A
37.3 A
47 A
Power supply capacity
8.7 kVA
10.7 kVA
16.1 kVA
24.5 kVA
30.9 kVA
Inrush current
4 A
2.5 A
2.5 A
2.5 A
2.5 A
Power loss
1)
Main circuit
102.72 W
115 W
153.18 W
271 W
390 W
Control circuit
35 W
36 W
36 W
36 W
36 W
Total 137.72 W 151 W 189.18 W 307 W 426 W
24 VDC power
supply
Voltage
24 V (-15% to +20%)
Maximum current 3 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED Series and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Series Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED Series
CategoryControl Unit
LanguageEnglish

Related product manuals