Commissioning Manual
80 6FC5397-4EP10-0BA8, 07/2018
Digital output interfaces - X200, X201
Pin assignment
Max. cross-section: 1.5 mm
2
(when using one cable per connection)
Rated digital output current: 250 mA
1 +24 V +24 V +24 V input (20.4 V to
Connecting according to the default PLC program
Note
End sleeves are necessary if you use two cables per connection.
Fasten the cables to the screw terminals and plug the terminals into interfaces X200, X201 correctly.