Appendix (Volume 2)
1027
Macro File Editing Rules
Example of File Contents
MenuMacroRun Register? 1 to 99 Applicable register number
KeyBusUtilityButton ME? ME1 to ME4, PP Control blocks on the
applicable bank
BANK? Bank1 to Bank5 Applicable bank
KeyBusUtilityButto
n?
1 to 32 Applicable button
UtilityStatus? On, Off, Current (a) Status of function assigned
to button
(a): Operates according to
currently assigned function
ClipRecall Device? FrameMemory1Clip
to
FrameMemory8Clip
Applicable clip
ClipType? Pair, Single File type of clip (pair/single)
Clip? Clip Name Name of clip (up to four
characters)
Device Record Device? 1 to 12 Applicable device
Line Content Description
1 PNL 0001PNL_0000.PMRMACROREG File header
2 #,Sample, Comment
3 Event?,Snapshot,Region?,ME1,Register?,1,Attribute?,Off,Time?,Current Simultaneously
recall
snapshots from
register number
1 in the M/E-1
and DME1
regions.
4 Continue?,Snapshot,Region?,DME1,Register?,1,Attribute?,Off,Time?,Current
5 Event?,MEXpt,ME?,ME2,MEBus?,A,Xpt?,121,VideoKey?,Video Select button
number 121 on
the M/E-2 A
bus.
Symbol Parameter name Arguments Description