Chapter 5 Wipes
334
Wipe Pattern Operations in the Multifunction Flexi Pad Control Block
Buttons for setting the wipe pattern limit
PTN LIMT (pattern limit): Enables the following settings for the pattern
limit using the control knobs.
LIMT SET (limit set): If you change the pattern size with the fader lever then
press this button, this sets the current size as the pattern limit.
a) At 0%, executing the transition has no effect at all.
b) At 100%, the transition can be executed with the same effect as with no pattern limit set, but
when the transition completes, background buses A and B are not interchanged.
Other buttons
EXIT: Exits the editing mode, and returns the memory recall section to wipe
snapshot mode.
KNOB 1/2: When the control knob adjustments are on two pages, this switches
between parameter group [1/2] and parameter group [2/2].
Wipe modify clear
When the [WIPE] button is held down, holding down the region selection
button for the selected region together returns all the wipe settings of the region
to the initial status settings.
For details of the initial status, see “Selecting the State After Powering On
(Start Up Menu)” in Chapter 18 (Volume 3).
Saving, Canceling, and Deleting Edited Wipe Patterns
Saving the edited wipe pattern as a snapshot
Holding down the [WIPE] button, press the button in the memory recall section
for the register in which you want to save.
The button you pressed lights yellow.
Buttons for registers in which wipe snapshots are already saved light orange.
Canceling a saved wipe snapshot
To cancel a wipe snapshot
Immediately after saving, hold down the [STOR STAT] button and press the
[UNDO] button.
Knob Parameter Adjustment Setting values
1 P Pattern limit range
0
a)
to +100
b)
(%)