Chapter 12 External Devices
733
Control of P-Bus Devices
Action command for an operation in the keyframe control block or
Multifunction Flexi Pad control block
• RUN: Trigger 1
• REWIND: Trigger 4
• NEXT KF: Trigger 7
• PREV KF: Trigger 8
Outputting an action command
As an example, to output a Recall, use the following procedure.
1
In the numeric keypad control block, press the [EFF] button, turning it on.
The [RCALL] button in the numeric keypad control block lights.
2
Press the [P-BUS] button in the numeric keypad control block, turning it
on, to select the P-Bus region.
3
Enter the number of the register (1 to 250) to be recalled with the numeric
keypad buttons.
4
Press the [ENTER] button in the numeric keypad control block.
This carries out the Recall.