UTILITY function
198 PM5D/PM5D-RH Owner’s Manual Reference section
In this screen you can prohibit console operation (Console
Lock) or prohibit editing for specific parameters (Parame-
ter Lock). Two passwords of differing levels can be
specified to allow locking and unlocking.
A SYSTEM PASSWORD
This is a permanent password (maximum of eight
characters) for the entire system. The password you
specify here is valid for the PARAMETER LOCK but-
ton (
2) and for the CONSOLE LOCK button (3).
However, you can perform the Lock operation even
without specifying a password.
If no password has been specified, this box will indi-
cate “--FREE--”. If a password has been specified,
asterisks (*) will be displayed to represent the charac-
ters of the password.
To set or change the password, click the button to
open the SYSTEM PASSWORD CHANGE window.
When setting the password for the first time, you will
input the same password twice for confirmation. To
change the password, you will input both the old pass-
word and the new password. By specifying a blank
entry as the new password, you can restore the state to
a condition in which no password has been set.
Note
The system password is remembered even when the power is
turned off. This means that if you forget the password, you will
be unable to defeat Parameter Lock or Console Lock except
by initializing the entire memory of the PM5D (
p.147).
Please be careful not to lose the system password.
B PARAMETER LOCK
This button sets/defeats Parameter Lock for the param-
eters selected in the LOCK PARAMETER SELECT area
(
4). If not even one parameter is selected, these but-
tons will be grayed-out and cannot be turned on. If the
system password has been set, clicking this button will
open the SYSTEM PASSWORD CHECK window,
where you will need to input the system password.
C CONSOLE LOCK
This button locks the console operations. If the system
password has been set, clicking this button will open
the SYSTEM PASSWORD CHECK window, where
you will need to input the system password.
D LOCK PARAMETER SELECT
If the PARAMETER LOCK button (2) is on, parame-
ters for which editing will be disabled can be selected
from the following table. As long as the PARAMETER
LOCK button (
2) is on, these parameters cannot be
edited.
E CONSOLE PASSWORD
This is a temporary password (maximum of eight char-
acters) that is separate from the system password. The
password you specify here is valid for the CONSOLE
LOCK button (
6). The method for setting or chang-
ing the password is the same as for the system
password.
Hint
The Console Password is cleared when the PM5D’s power is
turned off, and will return to the unset state (the box will indi-
cate “--FREE--”).
F CONSOLE LOCK
This button locks the console operations. If the con-
sole password has been set, clicking this button will
open the CONSOLE PASSWORD CHECK window,
where you will need to input the console password.
SECURITY screen
SECURITY
1
3
2
SYSTEM CONFIGU-
RATION
Changes to the settings of the
MIXER SETUP screen and the CAS-
CADE screen
WORD CLOCK
SETUP
Changes in the word clock setting
DITHER Changes in dither-related settings
INPUT PATCH
Changes to the input patch (and
NAME) settings
OUTPUT PATCH Changes to the output patch settings
INPUT CH ON/OFF Input channel on/off operations
OUTPUT CH ON/
OFF
Output channel on/off operations
MIX TO ST ON/OFF
MIX channel [TO STEREO] key
operations
DCA MUTE ON
DCA [MUTE] key On operations
(Off operations are not included)
4
5
6

Table of Contents

Other manuals for Yamaha PM5D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yamaha PM5D and is the answer not in the manual?

Yamaha PM5D Specifications

General IconGeneral
TypeDigital Mixing Console
Sampling Frequency44.1kHz, 48kHz
EQ4-band parametric EQ per channel
A/D Conversion24-bit
D/A Conversion24-bit
Number of Output Channels24
Internal Processing32bit
MeteringLED level meters
Frequency Response20Hz - 20kHz
THD+N<0.05%
ConnectivityMIDI, Ethernet
Dynamic ProcessingGate, compressor, limiter per channel
Number of Input Channels48 mono + 4 stereo
Dynamic Range110 dB typ