Removing the SAN Volume Controller 2145-8G4 PCI express riser card assembly
Use these instructions when you are prompted to remove the SAN Volume Controller 2145-8G4 PCI
express riser card assembly.
Note: Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a
static-protected mat or surface. For more information, see “Handling static-sensitive devices” on page xx.
To remove the SAN Volume Controller 2145-8G4 PCI express riser card assembly, follow the instructions
in “Removing the SAN Volume Controller 2145-8G4 Fibre Channel adapter assembly” on page 182.
Replacing the PCI express riser-card assembly
Use these instructions when you are prompted to replace the SAN Volume Controller PCI express riser
card assembly.
Replacing the SAN Volume Controller 2145-8A4 PCI express riser-card assembly
Use these instructions when you are prompted to replace the SAN Volume Controller 2145-8A4 PCI
express riser card assembly.
Follow the instructions in “Replacing the SAN Volume Controller 2145-8A4 Fibre Channel adapter
assembly” on page 187.
Replacing the SAN Volume Controller 2145-8G4 PCI express riser-card assembly
Use these instructions when you are prompted to replace the SAN Volume Controller 2145-8G4 PCI
express riser card assembly.
Follow the instructions in “Replacing the SAN Volume Controller 2145-8G4 Fibre Channel adapter
assembly” on page 188.
Removing the operator-information panel assembly
You might be prompted to remove the SAN Volume Controller operator-information panel.
Take precautions to avoid damage from static electricity. Wear an anti-static wrist strap and use a
static-protected mat or surface. For more information, see “Handling static-sensitive devices” on page xx.
Removing the SAN Volume Controller 2145-CG8 or 2145-CF8 operator-information
panel assembly
You can remove the operator-information panel assembly on a SAN Volume Controller 2145-CG8 or
2145-CF8.
Chapter 2. Removing and replacing parts 215
|
|

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller 2145-CG8 and is the answer not in the manual?

IBM SAN Volume Controller 2145-CG8 Specifications

General IconGeneral
BrandIBM
ModelSAN Volume Controller 2145-CG8
CategoryStorage
LanguageEnglish

Related product manuals