b. For each dot of thermal grease, use two divisions on the syringe scale, which is 0.02 ml of grease.
You will use about half the syringe contents for the nine dots. Figure 298 shows how the
microprocessor appears with the nine dots of grease.
c. Install the heat sink by gently squeezing it down onto the thermal grease and then tightening the
four retaining screws alternately and evenly.
7. If this is a Rev 1 node, repeat steps 5 on page 295 and 6 on page 296 for the second microprocessor
and heat sink. If this is a Rev 2 node, continue with the next step.
8. Replace either eight memory modules for the Rev 1 node or four memory modules for the Rev 2
node. See “Replacing the memory modules (DIMM)” on page 109.
9. Replace the right air baffle, which is shown in Figure 299 on page 298.
a. Locate the pin on the bottom of the air baffle in the locating hole on the system board.
b. Push the baffle backwards to locate it in place.
svc00413
Figure 297. Estimating the position of the thermal grease dots
svc00414
Figure 298. Complete set of nine thermal grease dots on the microprocessor
Chapter 2. Removing and replacing parts 297

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller 2145-CG8 and is the answer not in the manual?

IBM SAN Volume Controller 2145-CG8 Specifications

General IconGeneral
BrandIBM
ModelSAN Volume Controller 2145-CG8
CategoryStorage
LanguageEnglish

Related product manuals