User manual of EC160 elevator intelligent integrated machine Function parameters
99
Function
code
Instruction Setting range【default value】 Remarks
P6_00 Local communication address 1~247【1】
Not modify
in running
Function
code
Instruction Setting range【default value】 Remarks
P6_01
Communication baud rate
selection
0~5【4】
Not modify
in running
This parameter is used to set the data transmission rate between the upper computer and the
integrated machine.
0: 1200BPS 3: 9600BPS
1: 2400BPS 4: 19200BPS
2: 4800BPS 5: 38400BPS
The baud rate setting of the upper computer should be the same as that
of the integrated machine. The higher the baud rate, the faster the
communication speed is.
Function
code
Instruction Setting range【default value】 Remarks
P6_02 Data format 0~2【1】
Not modify
in running
The data format setting of the upper computer should be the same as that of the integrated
machine. Otherwise, communication cannot be implemented.
0: No parity (N, 8, 1) for RTU
1: Even parity (E, 8, 1) for RTU
2: Odd parity (O, 8, 1) for RTU
Function
code
Instruction Setting range【default value】 Remarks
P6_03
Communication response
enabling
0~1【0】
Not modify
in running
0: Enabled
1: Disabled