User manual of EC160 elevator intelligent integrated machine Installation and wiring
23
EC160-015-4 223 347 169 150 334.5
φ7 M6
EC160-018-4 290 426 233 235 410
φ7 M6
EC160-022-4 290 426 233 235 410 φ7
M6
EC160-030-4 290 426 233 235 410 φ7
M6
When design the control cabinet, the left and right space should be no
less than 50mm and the above and below space should be no less than
100mm to ensure enough cooling.
4.1.1 Terminals instruction
Figure 4-2 Terminals
No. Code Name Remarks
1 CN3/CN4
Peripheral signal
terminal
Digital input signal, analog input signal
2 CN5
Terminal for power and
internal/external hall
communication
DC24V input terminal, RS485
communication, CAN communication
3 CN6
High-voltage detection
terminal
AC/DC110V safety, car door lock, hall door
lock high-voltage detection
4 CN7 Relay output terminal 6 relay output terminals
5 CN10
Terminal for
synchronous master
ERN1387 or incremental encoder with U, V
and W