EasyManuals Logo
Home>INVT>Control Systems>EC160

INVT EC160 User Manual

INVT EC160
227 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
User manual of EC160 elevator intelligent integrated machine Debugging tools
49
5.5.7 Corresponding list of function parameters
Function
code
Name Detailed instruction of parameters
Default
value
P0 Group Master drive control
P0.00 Speed control mode
0: Vector control without PG
1: Vector control with PG
2: V/F control
1
P0.01
Rated speed of the
elevator
0.100~6.000m/s 1.750
P0.02
Max. speed of the
elevator
0.100~P0.01m/s 1.750
P0.03 Max. output frequency 10.00~400.00Hz 27.80
P0.04
Diameter of traction
sheave
100~2000mm 400
P0.05 Reduction ratio 1.00~100.00 1.00
P0.06
Suspension ratio of
traction rope
1~8 2
P0.07 Carrier frequency 1.0~16.0kHz 6.0
P0.08
Running direction
selection
0: Default direction
1: Reverse direction
0
P0.09
Motor parameters
autotuning
0: No operation
1: Rotating autotuning
2: Static autotuning
0
P0.10 Hoistway autotuning
0: No operation
1: Hoistway autotuning
0
P0.11
Car weighing
autotuning
0: No operation
1: Light load autotuning
2: Full load autotuning
3: Overload autotuning
0
P0.12
Data management
operation
0: No operation
1: Data storage after power loss
2: Facotry setting restore
3: Fault record clearance
0
P0.13 Reserved 0~2 0