User manual of EC160 elevator intelligent integrated machine Function parameters
80
6.5.2 Parameters setting---speed and deceleration distance
【main menu】
A system control
B fault record
C language selection
D parameters setting
inquiry
E password setting
F system autotuning
G data management
H system information
【parameters setting
inquiry】
P0 master drive
control
P1 speed and
deceleration distance
P2 motor parameters
P3 encoder
parameters
P4 running
comfortability
P5 elevator protection
parameters
P6 communication
setting
P7 drive information
PE factory only
【P1 speed and
deceleration distance】
00 increasing
acceleration 1
01 increasing
acceleration 2
02 acceleration speed
03 reducing
deceleration 1
04 reducing
deceleration 2
05 deceleration speed
06 door area
07 zero-speed
threshold
08 pre-opening speed
threshold
09 inspection speed
10 peristaltic landing
speed
11 UPS running speed
12 landing speed
13 autotuning speed
14 landing precision
Function
code
Instruction Setting range【default value】 Remarks
P1_00
Increasing acceleration 1 (fast
acceleration at the beginning
stage)
0.001~9.999m/s
3
【0.350】
Not modify
in running
P1_01
Increasing acceleration 2 (fast
acceleration at the end stage)
0.001~9.999m/s
3
【0.350】
P1_02 Acceleration speed 0.001~9.999m/s
2
【0.700】