User manual of EC160 elevator intelligent integrated machine Debugging at fast speed
154
inspection/automatic switch in the inspection position.
(4) Ensure the voltage between the power terminal of the door operator is 220V±7%VAC.
(5) Debug according to the instruction of the door operator.
(6) Check the opening and closing of the door operator.
A. Set the door in the automatic state and the door is closed.
B. Press the opening relay and the door opens.
C. Press the closing relay and the door closes.
D. When the door is open totally, press the UP/DOWN button, the door closes automatically.
(7) Check the door closed/open actions.
A. Stop the elevator in the leveling position and dial the inspection/automatic switch in the normal
position and the door is closed.
B. Monitor the automatic state in the manual controller.
3. Inspection of the beam
Check and correct according to the installation of the beam. In the automatic mode, enter to
monitor the input state:
(1) Switch off the power supply of the elevator and connect the car communication, and then switch
on the power supply.
(2) Confirm the display screen of the car is correct and change with the displaying on the manual
controller in the control cabinet.
(3) Short circuit the terminal resistor.
4. Connection inspection of the leveling sensor
(1) Connect the leveling sensor according to the diagram.
(2) Inspect the signal of the leveling sensor.
(3) Inspect the position of the limit switch.
A. The car runs up until to the up limit switch acts, then the sill of the car is above the sill of he hall
about 50mm.
B. The car runs down until to the down limit switch acts, then the sill of the car is below the sill of he
hall about 50mm.
C. Cross-circuit the up/down limit switch, and the car goes up/down until the safety switch acts, and
then the sill of the car is above the sill of he hall about 250mm.
D. The car runs down until to the down limit safety switch acts, then the sill of the car is below the
sill of he hall about 250mm.
E. After the adjustment, remove the cross-connection and restore the original connection.
5. Inspection and adjustment of the terminal forced deceleration switch
(1) Up terminal forced deceleration switch and down terminal forced deceleration switch