User manual of EC160 elevator intelligent integrated machine Function parameters
100
Function
code
Instruction Setting range【default value】 Remarks
P6_04 Communication response delay 0~20ms【0】
Not modify
in running
Reply delay refers to the interval time between the end of data receiving of the machine and the
reply data sending of the upper computer. If the reply delay time is less than the system
processing time, take the system processing time as reply delay reference. If the reply delay is
longer than the system processing time, after data processing, the system has to wait until the
reply delay time is reached before sending data to the upper computer.
Function
code
Instruction Setting range【default value】 Remarks
P6_05 Communication timeout fault 0~100.0s【0】
Not modify
in running
If the functional code is set to 0.0s, the communication delay time parameter is disabled.
When the functional code is set to be a valid value, if the interval between the current
communication and the next communication exceeds the communication delay time, the system
will alarm “485 communication fault” (Err118).
Normally, it is set to be “disabled”. If this parameter is set in a consecutive communication
system, communication state can be monitored.
Function
code
Instruction Setting range【default value】 Remarks
P6_08
Ethernet communication speed
setting
0~4【0】
Not modify
in running
0: 10M full duplex
1: 10M semi duplex
2: 100M full duplex
3: 100M semi duplex
4: Self-adaptation
Function
code
Instruction Setting range【default value】 Remarks
P6_09~P6_12 Set Ethernet IP address 0~255【192】 Not modify