User manual of EC160 elevator intelligent integrated machine Function parameters
82
Function
code
Instruction Setting rangedefault value Remarks
P1_07 Zero-speed threshold 0~0.050m/s0
Not modify
in running
Zero-speed threshold means the Min. running speed before braking. Generally, it does not need
setting.
Function
code
Instruction Setting rangedefault value Remarks
P1_08 Pre-opening speed threshold 0~0.500m/s0.050
Not modify
in running
When the running speed of the elevator is lower than the pre-opening speed threshold, the
pre-opening output will be allowed and Y5 will output at the same time.
Function
code
Instruction Setting rangedefault value Remarks
P1_09 Inspection speed 0~0.630m/s0.200
Not modify
in running
P1_10 Peristaltic landing speed 0~0.200m/s0.03
P1_11 UPS running speed 0~1.000m/s0.100
P1_12 Landing speed 0~1.000m/s0.200
P1_13 Autotuning speed 0~1.000m/s0.100
The above parameters are the Max. allowable speed of the elevator in different running modes.
Function
code
Instruction Setting rangedefault value Remarks
P1_14 Landing precision 0~100mm50
Not modify
in running
If the leveling overshoots, enlarge the running distance of the elevator on the basis of original
leveling precision; if the leveling lacks, reduce the running distance of the elevator on the basis of
original leveling precision.