User manual of EC160 elevator intelligent integrated machine Product overview
17
Model
Rated output
power (kW)
Rated output
current (A)
Braking unit
Min. braking
resistance
EC160-5R5-4 5.5 13.0 Built-in 55Ω/1500W
EC160-7R5-4 7.5 18.5 Built-in 50Ω/2000W
EC160-011-4 11.0 27.0 Built-in 40Ω/4000W
EC160-015-4 15.0 34.0 Built-in 32Ω/4500W
EC160-018-4 18.5 38.0 Built-in 28Ω/5000W
EC160-022-4 22.0 46.0 Built-in 22Ω/7000W
EC160-030-4 30.0 62.0 Built-in 20Ω/10000W
EC160-037-4 37.0 75.0 DBU-055-4 14Ω/11100W
EC160-045-4 45.0 92.0
DBU-055-4
11Ω/13500W
EC160-055-4 55.0 115.0
DBU-055-4
9Ω/16500W
EC160-1R5-S2 and EC160-2R2-S2 are single phase 220V input
suitable for villa elevators.
The external C3 filter meets CE standards.
The other power degree products are non-standard products. Please
contact with our company directly if need.
3.4 Technical specifications
Item Name Specification
Input/output
Input voltage AC 400V±15%
Input frequency 47~63Hz
Output voltage 0~rated input voltage
Output frequency 0~400Hz
Elevator
Highest floor 36
th
Max. running
speed
3m/s
Group control
quantity
8
Communication
mode
2 sets of CANbus communication terminal/2 sets of Modbus
communication terminal
Peripheral
interface
Digital low voltage
input port
24 digital low voltage input terminals, DC 24V/4.5~8mA