User manual of EC160 elevator intelligent integrated machine Function parameters
84
Function
code
Instruction Setting rangedefault value Remarks
P2_00 Motor type selection 0-11
Not modify
in running
Select the motor type
0: Asynchronous master
1: Synchronous master
After changing the motor type, it needs to change the corresponding
parameters of the encoder. When the synchronous changes into
asynchronous motor, P2_06~P2_10 will match according to the rated
power of the motor.
Function
code
Instruction Setting rangedefault value Remarks
P2_01 Rated power of the motor 0.1~150.0kW7.5
Not modify
in running
P2_02 Rated frequency of the motor 3Hz~400Hz27.8
P2_03 Rated speed of the motor 0~30000rpm167
P2_04 Rated voltage of the motor 0~460V380
P2_05 Rated current of the motor 0.1~1000.0A15
Input above parameters correctly when master autotuning. After modifying the rated power of the
asynchronous, P2_06~P2_10 will match according to the rated power of the motor.
Function
code
Instruction Setting rangedefault value Remarks
P2_06 Resistance of the stator 0~65.5351.41
Not modify
in running
P2_07 Resistance of the rotor 0~65.5351.41
P2_08
Inductance of the stator and
rotor
0~6553.5mH141
P2_09
Mutual inductance of the stator
and rotor
0~6553.5mH140
P2_10 Current without load 0~655.35A1.5
Above parameters will update automatically after autotuning of the master. These parameters are