User manual of EC160 elevator intelligent integrated machine Function parameters
84
Function
code
Instruction Setting range【default value】 Remarks
P2_00 Motor type selection 0-1【1】
Not modify
in running
Select the motor type
0: Asynchronous master
1: Synchronous master
After changing the motor type, it needs to change the corresponding
parameters of the encoder. When the synchronous changes into
asynchronous motor, P2_06~P2_10 will match according to the rated
power of the motor.
Function
code
Instruction Setting range【default value】 Remarks
P2_01 Rated power of the motor 0.1~150.0kW【7.5】
Not modify
in running
P2_02 Rated frequency of the motor 3Hz~400Hz【27.8】
P2_03 Rated speed of the motor 0~30000rpm【167】
P2_04 Rated voltage of the motor 0~460V【380】
P2_05 Rated current of the motor 0.1~1000.0A【15】
Input above parameters correctly when master autotuning. After modifying the rated power of the
asynchronous, P2_06~P2_10 will match according to the rated power of the motor.
Function
code
Instruction Setting range【default value】 Remarks
P2_06 Resistance of the stator 0~65.535Ω【1.41】
Not modify
in running
P2_07 Resistance of the rotor 0~65.535Ω【1.41】
P2_08
Inductance of the stator and
rotor
0~6553.5mH【141】
P2_09
Mutual inductance of the stator
and rotor
0~6553.5mH【140】
P2_10 Current without load 0~655.35A【1.5】
Above parameters will update automatically after autotuning of the master. These parameters are