User manual of EC160 elevator intelligent integrated machine Function parameters
139
6.5.21 Parameters setting---hoistway information
The parameters are used to check the floor height and installation distance of the deceleration
switch after the elevator autotuning.
main menu
A system control
B fault record
C language selection
D parameters setting
inquiry
E password setting
F system autotuning
G data management
H system
information
parameters setting
inquiry
P0 master drive
control
P1 speed and
deceleration distance
P2 motor parameters
P3 encoder
parameters
P4 running
comfortability
P5 elevator protection
parameters
P6 communication
setting
P7 drive information
PE factory only
A1 floor setting
A2 floor displaying
H0 logic of the IO
control board
H1 logic of the car
control board
H2 front door
stopping floor
H3 rear door stopping
floor
H4 front/ rear door
stopping floor
L0 parallel and group
control setting
T0 time setting
F0 function setting
U0 calling signal
U1 system monitoring
U2 hoistway
information
U2 hoistway
information
Total height of the floor
Low speed down forced
deceleration distance
Low speed up forced
deceleration distance
Medium speed down
forced deceleration
distance
Medium speed up forced
deceleration distance
High speed down forced
deceleration distance
High speed up forced
deceleration distance
Longest floor distance
Shortest floor distance